Railway Rails - Environmentally Assisted Sulphide Stress Corrosion Cracking in Railway Tracks

Topics Covered

Background

Causes of Rail Failure

Detection and Examination of Rail Associated Hardware

Case Study – Rail Failure in an Underground Rail System

Initial Examination

Detailed Examination

Magnetic Particle Inspection

Metallurgical Examination

Hydrogen Testing

Environmental Inspection

Chemical Testing

Sulphide Stress Corrosion Cracking

The Path to Failure

Sulphide Stress Corrosion Cracking and its Elimination

Summary

Background

Today, commuters in the UK face delays and sometimes derailments, as the rail network continues to suffer from the problems of worn out and broken rails. Heightened by the Hatfield train derailment in October 2000, the problem of broken rails caused by mechanical failure has continued to hit the headlines in recent years.

Causes of Rail Failure

The derailment at Hatfield was caused by gauge corner cracking. But this form of mechanical failure is not the only failure mechanism of concern for railway rails, particularly rails on underground systems that may suffer water ingress. Corrosion, materials and environmental technology group CAPCIS recently investigated a rail failure that was not the result of fatigue cracking. After extensive testing, CAPCIS concluded that the rail had failed due to sulphide stress corrosion cracking (SSCC) - a form of environmentally assisted cracking.

Detection and Examination of Rail Associated Hardware

The detection of cracks in rails usually involves the visual examination of the rails, clips and base plates, and ultrasonic examinations of the railhead. These inspections are focussed primarily on detecting fatigue cracks and rail wear caused by the repeated contact with train wheels. Corrosion problems on dc-powered traction systems are usually associated with stray currents. The ‘leakage’ of electrical current from its intended path can cause localised corrosion of the rail or other equipment where the current leaves the component.

Case Study – Rail Failure in an Underground Rail System

During a project looking at stray current and other corrosion issues on an underground dc traction system, CAPCIS was asked to investigate a somewhat unusual failure of a rail. In-situ photographs of the fractured rail taken following the incident suggested that the rail web had suffered severe thinning leading to overload failure.

Initial Examination

However, upon receipt of the rail sections and a cursory examination of the fracture faces, it was clear that corrosion and thinning were not the direct cause of the failure, figure 1.

AZoM - metals, ceramics, polymers and composites : fracture surface of a failed railway track rail

Figure 1. Fracture surface of the failed rail.

Detailed Examination

Detailed examination of the fracture face revealed no obvious signs of fatigue cracking, and SEM examinations of the railhead and web showed only brittle fractures. In contrast to the railhead, the web and foot of the rail exhibited extensive corrosion, indicating that this was not a single event fracture.

Magnetic Particle Inspection

To check for the presence of any surface cracks the railhead was examined using magnetic particle inspection. A number of elongated S-shaped cracks were found running along the worn gauge corner of the rail, figure 2. These cracks, referred to as ‘head checking’, were typically 10mm in length, but there was no indication that the failure had originated at these surface cracks.

AZoM - metals, ceramics, polymers and composites : head checking in a failed railway track

Figure 2. Head checking of the rail had not contributed to the failure.

Metallurgical Examination

However, further metallurgical examination of the web and foot of the fractured rail revealed fine cracks typical of those caused by hydrogen embrittlement of the steel, figure 3. The cracks ran mainly parallel to the fracture faces and did not appear to be associated with any of the small manganese sulphide inclusions running through the steel.

AZoM - Metals, ceramics, polymers and composites : Hydrogen cracks in a railway track

Figure 3. Metallographic examination of the fracture revealed classic step-wise hydrogen cracks in the web and foot of the rail.

Hydrogen Testing

Hydrogen levels in quality as‑manufactured steel are typically 1-2 ppm. The chemical analysis of several sections from the web, foot and head of the rail revealed elevated hydrogen levels in the steel far above those expected in modern rail steel. Values of 2 ppm were recorded at the top of the web and values of 5 ppm were found at the bottom of the web. The increased levels were found to be the result of environmental hydrogen absorption.

Environmental Inspection

During inspections, it had been noted that while some areas of the tunnels were apparently dry, others suffered water ingress in places. The tunnel environment was also found to be damp and warm even though the ambient temperature at street level was somewhat cooler. The source of the hydrogen was finally traced to stagnant water pools beside and beneath the rails, which were found covered with a white ‘scum’. When disturbed, hydrogen sulphide gas (H2S) could be smelt immediately and lead acetate paper turned brown, also indicating its presence.

Chemical Testing

To confirm the cause of the failure, azide tests (a chemical test carried out to determine whether a material has been exposed to an environment containing sulphides) were carried out on the rail, and a sample of the water was returned to the laboratory for testing. A high level of sulphate-reducing bacteria (104 SRB per ml) was found in the water. SRB are micro-organisms that chemically reduce sulphate ions in the water to sulphide. The corrosion reaction involving H2S produces monatomic hydrogen (H0) at the corroding surface that should combine to form H2 gas, but the presence of sulphide species retards or poisons this combination reaction so that the hydrogen diffuses into the steel. Positive azide tests and the presence of SRB led to the conclusion that the rail almost certainly failed due to sulphide stress corrosion cracking.

Sulphide Stress Corrosion Cracking

SSCC was first recognised in the 1950’s in the oil and gas industry and occurs in high strength steels at relatively low absorbed hydrogen levels. This form of cracking is highly dependent on the steel composition, microstructure, strength and total stress level (applied and residual) - the higher the strength of the steel, the greater the susceptibility to hydrogen embrittlement.

The Path to Failure

The presence of the hydrogen cracks explained the corroded regions on the fracture face. Small cracks formed and grew with time to become surface emergent, exposing the crack faces to the external environment allowing further corrosion and hydrogen diffusion. The cracks eventually reached a critical size such that the rail could not withstand the stresses induced by the passage of trains and a brittle overload failure occurred.

Sulphide Stress Corrosion Cracking and its Elimination

While this failure may not be unique it was unusual. CAPCIS has encountered many SSCC failures in the oil and gas industry, but has never seen such a failure in a section of rail. In the past, hydrogen-related failures of rails, such as tache ovales, have been caused by fatigue cracking starting at small hydrogen cracks in the railhead, but controlling hydrogen levels in the as-made steel has largely eliminated these failures.

Summary

While the detection of stray current corrosion and fatigue cracking of rails is fairly straight forward, the detection of SSCC would be extremely difficult for rail engineers. On-site azide tests are impractical and effective ultrasonic examination of a corroded rail web and foot would require extensive cleaning. Atmospheric H2S can be smelt, but the source is not always readily apparent. Add to this the fact that the detection of SRB requires a laboratory test and the diagnosis of SSCC is fraught with practical problems. The easiest way to minimise the risk of producing conditions conductive to SSCC is by controlling the tunnel environment and preventing water ingress and stagnation.

 

Source: Materials World, Vol. 11, no. 2, pp. 25-26 February 2003

 

For more information on this source please visit The Institute of Materials, Minerals and Mining.

 

Tell Us What You Think

Do you have a review, update or anything you would like to add to this article?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.