Background
Particle Technology Labs is a premier service laboratory, dedicated to quality particle size and characterization. Our services include but are not limited to:
Photon Correlation
Particle size of nano-sized particles measured on an intensity basis.
Photon Correlation Instrumentation Available
PTL has the following photon correlation equipment available:
- Malvern Zetasizer Nano
- Microtrac UPA 150
- Nicomp 380/ZLS
Malvern Zetasizer Nano
Features of Malvern Zetasizer Nano
- Technology allows measurements of samples with little or no dilution
- Uses a unique disposable zeta potential cell to ensure no cross contamination of samples
- Can analyze liquid and powder suspensions
- Particle size reported on intensity and volume basis
- Zeta Potential in aqueous and non-aqueous fluids
Figure 1. Malvern Zetasizer Nano
Malvern Zetasizer Nano is ideal for the following applications
- Particle Size - measurements of particle size from 0.6nm - 6µm
- Zeta Potential - measurements 3nm - 10µm
Recommendations for optimal output
- Viscosity of carrier fluid at desired analytical temperature
- Dielectric constant of carrier fluid (applicable for Zeta Potential)
- Refractive Index and imaginary number if available
- Recommended amount of sample needed: 100 mg (dry sample) 20 mL (wet sample)
Microtrac UPA 150
Features of Microtrac UPA 150
- Analytical range: approx 3nm - 6µm
- Can analyze liquid and powder suspensions (organic or inorganic solvents) in most carrier fluids
- Reports data on a Volume and Intensity basis
Figure 2. Microtrac UPA 150
Microtrac UPA 150 is ideal for the following applications
- Particle size distribution measurement
- Quality control
Recommendations for optimal output
- Viscosity of the carrier fluid at two temperatures (PTL has viscosity information on many common carrier fluids, for further information please call)
- Refractive index (recommended)
- Recommended amount of sample needed: 1 to 5 grams (dry sample) 10 to 50mL (wet sample)
Nicomp 380/ZLS
Features of Nicomp 380/ZLS
- Analytical range: approx 3nm - 1µm
- Classic technology within dye/pigment, emulsion, and protein industries
- Reports data on a Volume, and Intensity basis
- Zeta Potential determination
Figure 3. Nicomp 380/ZLS
Nicomp 380/ZLS is ideal for the following applications
- Particle size distribution measurement
- Quality control
Recommendations for optimal output
- Viscosity at one temperature
- Refractive index (recommended)
- Recommended amount of sample needed: 500mg to 10g (dry sample) 3 to 20mL (wet sample)
Source: Particle Technology Labs
For more information on this source please visit Particle Technology Labs