Turnkey Solution for UHV Temperature Programmed Desorption Studies from Hiden

The new TPD Workstation from Hiden Analytical is a complete turnkey station for UHV temperature programmed desorption studies and is suited to both quality control and to research applications. Applicable technologies include photovoltaics, metallurgy and semiconductor and thin-film studies.

The sample heating stage is fully programmable to 1000°C and is mounted within a stainless steel bellows-sealed linear drive for precise sample positioning close to the mass spectrometer analyser. The system features the fast, Hiden 3F/PIC quadrupole with pulse ion counting detection for highest sensitivity together with data collection rates in excess of 500 data points per second.

The close sample-to-analyser proximity ensures high collection efficiency and enables routine operation with sample size of just 1 sq.cm. The integrated Hiden TPD thermal analysis software provides complete control of experimental protocols including sample temperature, analyser parameters and data acquisition and display. The TPD analysis routines include peak integration and peak de-convolution, with real-time data views in 3D illustrating species evolved both with temperature and with time.

The system is totally UHV compatible, with a fast sample load lock and easy-glide magnetic transfer mechanism for ultimate vacuum integrity. Positive sample placement is directly onto the horizontal heater surface, aided by the three viewports and the high-intensity illuminator. A thermocouple contacts directly to the sample for positive thermal control, and internal water cooled heat-shields inhibit degassing due to radiant heat.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Hiden Analytical. (2019, February 10). Turnkey Solution for UHV Temperature Programmed Desorption Studies from Hiden. AZoM. Retrieved on November 21, 2024 from https://www.azom.com/news.aspx?newsID=25552.

  • MLA

    Hiden Analytical. "Turnkey Solution for UHV Temperature Programmed Desorption Studies from Hiden". AZoM. 21 November 2024. <https://www.azom.com/news.aspx?newsID=25552>.

  • Chicago

    Hiden Analytical. "Turnkey Solution for UHV Temperature Programmed Desorption Studies from Hiden". AZoM. https://www.azom.com/news.aspx?newsID=25552. (accessed November 21, 2024).

  • Harvard

    Hiden Analytical. 2019. Turnkey Solution for UHV Temperature Programmed Desorption Studies from Hiden. AZoM, viewed 21 November 2024, https://www.azom.com/news.aspx?newsID=25552.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.