New ABB Endura AZ40 Analyzer Measures Oxygen and Unburned Fuel to Optimize Industrial Combustion

ABB’s new easy-to-use operator interface and updated electronics for its combustibles gas analyzer

ABB’s Measurement & Analytics business announced a new oxygen and combustibles analyzer for measuring the efficiency of fossil-fired boilers and process heaters used in power generation, incineration, petrochemical, and iron and steel production.

Replacing ABB’s proven SMA90 system, the new Endura AZ40 analyzer simplifies accurately fine-tuning combustion processes. The result is greater efficiency, lower fuel costs, and reduced NOx pollution.

For optimum combustion, excess air must be present to burn all the fuel. But too much oxygen reduces efficiency and/or increases NOx production. Unburned fuel represents wasted energy and poses a safety risk.

The correct level of excess air depends on a variety of factors, including variations in atmospheric pressure and humidity, the fuel's heating value, and the performance of the boiler plant. Measuring oxygen alone does not provide an accurate picture of combustion efficiency.

Using two sensors, ABB's Endura AZ40 analyzer continuously monitors combustion waste gases to measure both excess air and unburned fuel. The analyzer provides an unburned fuel measurement in terms of carbon monoxide equivalent (COe). The COe reading supplements the net oxygen measurement to permit further trimming of combustion efficiency.

The analyzer consists of a sensor assembly, probe with filter assembly, transmitter, and interconnecting cable. The sensor assembly mounts to a duct or process wall, with the probe extending into the flue gas stream.

Available in lengths up to 8+ feet (2.5 meters) and suitable for temperatures to 3,000°F (1650°C), the probe continuously draws in the sample for analysis. Automatic sensor calibration uses test gases of known concentrations to calibrate both sensors and ensure continuous accuracy.

A variety of built-in features minimizes maintenance and provides operator convenience. For example, high efficiency filters and optional blowback prevent clogging of the Endura AZ40 probe head filter. A heated manifold avoids acid corrosion of the sensor assembly. Advanced diagnostic and verification functions ensure proper analyzer operation through regular self-checks on critical variables. The analyzer's HMI shares the same look and feel as ABB’s other instrumentation. Users can quickly and easily access, program, and adjust settings and operational data from one screen.

The Endura AZ40 analyzer is fully backwards-compatible and can be retrofitted in the field to ABB’s previous generation of SMA 90 combustibles analyzers.

For more information about the ABB Endura AZ40 combustion analyzer, visit here

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    ABB Measurement & Analytics. (2019, February 08). New ABB Endura AZ40 Analyzer Measures Oxygen and Unburned Fuel to Optimize Industrial Combustion. AZoM. Retrieved on November 21, 2024 from https://www.azom.com/news.aspx?newsID=45004.

  • MLA

    ABB Measurement & Analytics. "New ABB Endura AZ40 Analyzer Measures Oxygen and Unburned Fuel to Optimize Industrial Combustion". AZoM. 21 November 2024. <https://www.azom.com/news.aspx?newsID=45004>.

  • Chicago

    ABB Measurement & Analytics. "New ABB Endura AZ40 Analyzer Measures Oxygen and Unburned Fuel to Optimize Industrial Combustion". AZoM. https://www.azom.com/news.aspx?newsID=45004. (accessed November 21, 2024).

  • Harvard

    ABB Measurement & Analytics. 2019. New ABB Endura AZ40 Analyzer Measures Oxygen and Unburned Fuel to Optimize Industrial Combustion. AZoM, viewed 21 November 2024, https://www.azom.com/news.aspx?newsID=45004.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.