Posted in | News | Materials Research

The Hiden Transient-MS Analyser for Fast Gas Processes

The Hiden HPR-20 QIC TMS Transient Mass Spectrometer system is specifically configured for analysis of fast gas reaction processes operating through a broad pressure regime from 2 bar down to a low 100 mbar.  

HPR-20 QIC TMS Transient MS

Applications include flash-heating studies, respiratory analysis, sorption/desorption rate monitoring and assessment of gas/surface interaction kinetics. The compact benchtop system features the Hiden 3F/PIC series triple-filter quadrupole for optimum sensitivity, species identification and contamination resistance. The fast digital detector system provides a wide dynamic range through 7 continuous decades with a sampling rate capability in excess of 500 data points per second. Individual gaseous species may be selected and monitored within 6 milliseconds, with pulse profile resolution (5% to 95% peak height) in just 60 milliseconds. Sampling from the process is via an inert quartz-lined heated interface, process gases being exposed to quartz and platinum surfaces prior to analysis to maintain sample integrity. The APSI soft ionisation operating mode minimises ion fragmentation for simplification of complex mass spectra.  

The Transient system monitors gases and vapours with molecular weights to 300amu with higher mass ranges available for specialised applications, and systems include provision for import of two external process parameters, temperature and/or weight for example, for integration with the mass spectral data.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Hiden Analytical. (2019, March 17). The Hiden Transient-MS Analyser for Fast Gas Processes. AZoM. Retrieved on November 23, 2024 from https://www.azom.com/news.aspx?newsID=45622.

  • MLA

    Hiden Analytical. "The Hiden Transient-MS Analyser for Fast Gas Processes". AZoM. 23 November 2024. <https://www.azom.com/news.aspx?newsID=45622>.

  • Chicago

    Hiden Analytical. "The Hiden Transient-MS Analyser for Fast Gas Processes". AZoM. https://www.azom.com/news.aspx?newsID=45622. (accessed November 23, 2024).

  • Harvard

    Hiden Analytical. 2019. The Hiden Transient-MS Analyser for Fast Gas Processes. AZoM, viewed 23 November 2024, https://www.azom.com/news.aspx?newsID=45622.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.