Rapid Assessment of the Stability of Colloids & Dispersions

The Stabino® II from Analytik is a fast and easy-to-operate zeta potential instrument for analysing and optimising the stability of colloids and dispersions, based on measurement of streaming potential.

Stabino® II zeta potential instrument


Determining the stability of colloids or dispersions is a critical factor in quality assurance or the development and formulation of new products. Many analytical systems for determining stability are based on electrophoresis techniques that rely on a limited number of low-resolution measurements of the zeta potential. These systems can be slow and imprecise leading to an inconclusive analysis of the colloid/dispersion stability and incorrectly formulated products. 

Based upon rapid pH and polyelectrolyte titrations, the Stabino® II is able to provide very fast, precise and reproducible measurement of the surface charge of particles in the range of 0.3 nm to 300 µm in just minutes. With each measuring point, the Stabino® II provides valuable information about the conductivity, zeta potential, streaming potential, temperature and pH of your sample. Benefiting from a unique oscillating piston design the Stabino® II provides continuous sample mixing avoiding sedimentation of samples (0.3 nm to 300 µm) – often a problem when a titration approaches the iso-electric point.

The non-optical measuring principle of the Stabino II enables the assessment of stability of colloids and dispersions at their original concentration (up to 40% by volume). Due to the additional titration capability, stability ranges and aging processes can be detected very quickly. The influence of the individual titration additions on the stability can also be determined and optimized during formulation and shortens the development time. The determination of the isoelectric point and the charge titration are important features in the quality control of products or starting materials and help to select suitable starting materials.

Stabino® II operating principle: streaming potential measurement by immobilising the nano particle and shearing the ion cloud from the diffuse layer to measure zeta potential


Intuitive, easy-to-use software on the Stabino® II makes setting up a measurement extremely quick and easy. Just pour in 1 - 10 mL sample into the Teflon beaker of the Stabino® II, open the software and start the measurement. Using Stabino® II software, your entire titration can be tracked in real-time, with each titrated droplet a zeta potential measuring point is generated on the graph that includes all 5 measurement parameters. 

Applications that can benefit from the unique measurement capabilities of the Stabino® II include the printing industry, pigments, ceramics, pharmaceutical formulation, brewing, beverages, coatings, and material science.

For further information on Stabino® II please visit https://analytik.co.uk/stabino-zeta-potential-analyser-for-optimising-colloids-and-dispersions/ or contact Analytik Ltd. on +44(0)1954 232 776 or email [email protected].

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Analytik Ltd. (2021, January 27). Rapid Assessment of the Stability of Colloids & Dispersions. AZoM. Retrieved on November 21, 2024 from https://www.azom.com/news.aspx?newsID=55427.

  • MLA

    Analytik Ltd. "Rapid Assessment of the Stability of Colloids & Dispersions". AZoM. 21 November 2024. <https://www.azom.com/news.aspx?newsID=55427>.

  • Chicago

    Analytik Ltd. "Rapid Assessment of the Stability of Colloids & Dispersions". AZoM. https://www.azom.com/news.aspx?newsID=55427. (accessed November 21, 2024).

  • Harvard

    Analytik Ltd. 2021. Rapid Assessment of the Stability of Colloids & Dispersions. AZoM, viewed 21 November 2024, https://www.azom.com/news.aspx?newsID=55427.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.