IKA’s Dry Block Heater 3 is a digital block heater for three aluminum blocks; designed to provide precise temperature control in small vessels.
The included PT 1000 temperature sensor allows direct control of temperature within the vessel, and it can be used with PCR strips, PCR tubes, microplates, cuvettes and Greiner tubes.
The block heater is ideal for the determination of melting and boiling points, incubation and activation of cultures, enzyme reactions, DNA denaturation, immunoassays, culture media tests, coagulation tests, blood-urea-nitrogen determination and in situ hybridizations.
Key Features
- Stepless adjustable temperature up to 120 °C
- Countdown timer function, adjustable from 1 minute to 99 hours 59 minutes
- Counter function that displays heating time
- Fixed safety circuit
- Highly versatile, with a large number of blocks
- Error code display
- Audible signal to notify the user that the test has finished
Technical Data
- Width: 151 mm
- Height: 73 mm
- Heat output: 330 W
- Adjustment and display resolution: 1 K
- Temperature stability within the blocks at 60 °C *: 0.4± °C
- Time setting max.: 5999 min
- Temperature stability within the blocks at 37 °C *: 0.2± °C
- Set-up plate dimensions: 96 x 228 mm
- Temperature Homogenity @ 37 °C *: 0.3 K
- PT 1000 variation;DIN EN 60751 Kl. A: ≤ ± (0.15 +0.002xITI)K
- Voltage: 220 - 240/115/100 V
- Power input: 330 W
- Weight: 1.6 kg
- Temperature Homogenity @ 60 °C *: 0.6 K
- Heatingrate / Heat up time with external sensor *: 4 K/min
- Fixed safety circuit : 150 °C
- Heating temperature min.: room temp. +5° °C
- Set-up plate material: Aluminium alloy
- Connection for ext. temperature sensor: CT (DIN12878)
- Temperature display: yes
- Protection class according to DIN EN 60529: IP 21
- USB interface: no
- Timer: yes
- Number of blocks: 3
- Permissible ambient temperature min.: 5 °C
- Depth: 380 mm
- Heating temperature max.: 120 °C
- Time setting min.: 1 min
- Frequency: 50/60 Hz
- Permissible ambient temperature max.: 40 °C
- Permissible relative humidity: 80%
- RS 232 interface: no
* Measured in IKA DBH Testingblock: Refer Manual for more details