Digital Pressure Gauge for Differential Pressures for High Accuracy

The DPGM409 digital differential pressure gauge from OMEGA incorporates a rugged 316SS enclosure designed for marine and washdown applications with a precision 0.08% accuracy pressure transducer and 316L SS wetted parts and body. The result is a digital pressure gauge that is extremely durable.

This differential pressure digital gauge functions perfectly with hydraulic oil, air or water as well as several other fluids.

  • Hi and lo alarms standard
  • Easy to read 25 mm backlit LCD display
  • 5-Point NIST traceable calibration
  • Wet/wet differential pressure measurement
  • High 0.08% accuracy
  • MIN/MAX/AVG reading
  • Bar graph on display
  • IP65 (NEMA-4X) enclosure
  • Battery powered with extended battery life
  • G¼ pressure connections standard - others available
  • User selectable analogue output 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA
  • Wireless transmitter option sends reading to remote location and comprises of charting and data logging software

Specifications

The key specifications of the DPGM409 digital differential pressure gauge are as follows:

  • Accuracy (Combined Linearity, Hysteresis and Repeatability): ±0.08% BSL
  • Storage Temperature: -40 to 82 °C
  • Operating Temperature: -18 to 66 °C
  • Thermal Effects (Over Operating Range):
    • Zero Balance:
      • Ranges 25 mb to 70 mb: ±1% span
      • Ranges >70 mb: ±0.5% span
    • Span Setting:
      • Ranges 25 mb to 70 mb: ±1% span
      • Ranges >70 mb: ±0.5% span
  • Minimum Resistance Between Transducer Body and Any Wire: 100MO @ 50 Vdc
  • Pressure Cycles: 1 million minimum
  • Long Term Stability (1-yr.): ±0.1% FS typical
  • Analogue Output: User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required).
    Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA
    Bidirectional ranges have a unidirectional analogue output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc.
    Analogue output is independently scalable
  • Analogue Output Cable: 2.7 m with ferrite core (included)
  • Analogue Output Accuracy: 0.08% typical (0.15% maximum in RF field @ 10V/m)
  • Line/Static Pressure: 500 psi maximum applied to both sides simultaneously
  • Proof Pressure (differential):
    • 25 mb: = 10 times range
    • 70 mb: = 6 times range
    • 170 mb to 50 Bar: = 4 times range
  • Hi-Side Containment Pressure (Differential):
    • 25 to 350 mb: To 1000 psi
    • 1 to 50 bar: To 3000 psi
  • Display: 4-digit LCD with user Selectable backlighting, (9999 count) 25 mm character height
  • Sample/Display Range: User selectable from 0.38 to 30 seconds (preset to 1/second)
  • Computer Interface: USB connection for set-up, cable included
  • Pressure Connection: G ¼ male
  • Power: One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3V)
  • Battery Life (Typical): Up to 4-years
  • Enclosure Material: 316 Stainless Steel and ABS centre gasket
  • Enclosure Finish: Electropolished
  • Enclosure Environmental Rating: Weatherproof, IP65
  • Sensor Wetted Parts: 316L stainless steel
  • Dimensions:
    • Display: 115 D x 89 W x 74 mm H
    • Sensor: 72 to 89 mm L below display, 80 mm wide
  • Weight: 1 kg typical depending upon configuration
  • Front Panel Functions:
    • Backlight: Manually turns backlight on/off
    • Min/Max: Recalls min/max values
    • Zero/Clear: Zeros display or clears min/max
  • Software Settings (via USB)
  • Update Rate: 4 options, 10, 5, 2, 1 times per second
  • Units: psi, inHg, inH2O, bar, mbar
  • Lock: Allows the lock-out of front panel functions
  • Alarms: User selectable “High” and “Low” alarm limits (open collector)
  • Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute
  • Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging
  • Calibrate: Zero and Span
  • Overrange Indication: “_ _ _ _”

Wireless Option Specifications

  • Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec
  • Radio Frequency (RF) Transceiver:
    • Carrier: ISM 2.4 GHz
    • RF Output: 10 dBm (10 mW)
    • Range of RF Link: Up to 120 m outdoors (line of sight); Up to 40 m indoors/urban
  • Included Software: Requires Windows® 7 (32 bit); XP, Vista
  • Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.