Investigating High-Temperature Corrosion Resistance of Structural Materials for Fusion Reactors

Do two promising structural materials corrode at very high temperatures when in contact with "liquid metal fuel breeders" in fusion reactors- Researchers of Tokyo Tech, YNU and QST now have the answer. This high-temperature compatibility of reactor structural materials with the liquid breeder-;a lining around the reactor core that absorbs and traps the high energy neutrons produced in the plasma inside the reactor-;is key to the success of a fusion reactor design.

Fusion reactors could be a powerful means of generating clean electricity and currently, several potential designs are being explored. In a fusion reactor, the fusion of two nuclei releases massive amounts of energy. This energy is trapped as heat in a "breeding blanket (BB)," typically a liquid lithium alloy, surrounding the reactor core. This heat is then used to run a turbine and generate electricity. The BB also has an essential function of fusion fuel breeding, creating a closed fuel cycle for the endless operation of the reactors without fuel depletion.

The operation of BB at extremely high temperature over 1173 K serves the attractive function to produce hydrogen from water, which is a promising technology to realize a carbon-neutral society. This is possible because the BB heats up to over 1173 K by absorbing the energy from the fusion reaction. At such temperatures, there is the risk of structural materials in contact with the BB becoming corroded, compromising the safety and stability of the reactors. It is, thus, necessary to find structural materials that are chemically compatible with the BB material at these temperatures.

One type of BB currently being explored is the liquid metal BB. A promising candidate for such BBs is liquid lithium lead (LiPb) alloy. As candidates for structural materials compatible with liquid LiPb at very high temperatures, a certain silicon carbide (SiC) material, CVD-SiC, and an iron-chromium-aluminum (FeCrAl) alloy pre-oxidized in air are being explored. But information on this compatibility is lacking beyond 973 K.

Now, a team of scientists from Tokyo Institute of Technology (Tokyo Tech), National Institutes for Quantum Science and Technology(QST), and Yokohama National University(YNU), Japan, led by Professor Masatoshi Kondo from Tokyo Tech, have demonstrated compatibility at much higher temperatures. Their findings are published in Corrosion Science. "Our study makes clear the nuances of the corrosion resistance mechanism of CVD-SiC and FeCrAl alloys in liquid LiPb up to 1173 K," Prof Kondo explains.

The team first synthesized high-purity LiPb by melting and mixing granules of Li and Pb in an apparatus under vacuum conditions. They then heated the alloy to the aforementioned temperatures, at which it was liquified. Samples of CVD-SiC and two variants of the FeCrAl alloy-;with and without pre-oxidation treatment to form an α-Al2O3 surface layer-;were placed in this liquid LiPb for 250 hours for corrosion testing. Prof. Kondo observes, "An interesting finding is that, contrary to previous literature, oxidation pre-treatment to form an α-Al2O3 layer did not provide corrosion resistance beyond 1023 K."

Cross-sections of the retrieved samples showed that CVD-SiC reacted with impurities in the LiPb alloy to form a layer of complex oxides, which then provided it with corrosion resistance. The untreated FeCrAl alloy formed a layer of the oxide γ-LiAlO2 upon reaction with LiPb, which then acted as an anti-corrosion barrier. In the case of the pre-treated FeCrAl, the α-Al2O3 surface layer provided corrosion resistance at 873 K but transformed into γ-LiAlO2 at 1173 K, and it was γ-LiAlO2 that then provided corrosion resistance.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.